Subscribe to our Newsletter
Model No: WM-IP02
Infusion Pump
Quantity :
WM-IP02 Infusion Pump Features:
1. Infusion Pump is with the classic vertical design. The software compensation error is within±5% after calibration. It is widely used in ICU, NICU, pediatrics, internal medicine, surgery, obstetrics and gynecology, oncology, emergency department and outpatient infusion room.
2. Double CPU and numeric keypad make it safe and more user friendly.
3. Adjustable Levels Setting: 10 levels setting for occlusion, air bubble and alarm volume
4. Strong Battery Backup: 3000mAh battery and backup time more than 10hrs.
5. User Friendly: Big Screen and numeric keypad
6. Dual Occlusion Sensor: Up and down occlusion sensor with DPS system
7. Infusion Mode: Volume mode, time mode
WM-IP02 Infusion Pump Technical Specification:
Infusion Mode | Volume Mode, Time Mode, Drug Mode |
Rate Unit | ml/h, volume/time, d/min |
IV Sets | Standard single use IV sets ( 10,15,20,60d/mL, with diameter 3.4 ~4.5mm) |
Flow Rate | 1.0ml/h~1200ml/h 1.0d/min~400d/min |
Increment | 1.0-99.9ml/h in 0.1ml/h step;100-1200ml/ in 1ml/h step 1-400d/min in 1d/min step; |
Deviation | Flow Rate:≤5%(after calibration) |
VTBI | 0.1~9999.9 ml |
Total Volume | 0.0~9999.9 ml |
Time | 1min~99h00min |
Purge Rate | 600ml/h,display purge volume |
KVO | 1.0ml/h~5.0ml/h,adjustable |
Keypad | Numeric keypad, |
BOLUS | Bolus function available, flow rate adjustable |
Night Mode | Screen to be dim automatically in 5mins after standby time expired. |
Occlusion pressure detector | downstream pressure detection, 40KPa~130KPa, 10 levels adjustable with dynamic pressure value display |
Air Bubble Detector | Ultrasonic detection, ≥50ul,Single bubble volume: 50~300 μl, 10 levels adjustable. |
Volume | 10 levels adjustable |
Motor Anti-reverse Function | Anti-reverse function to prevent upstream |
IV Set Management | Open system, accept different IV brands after calibration |
Self-Testing | Self-Testing before startup and during infusion |
Audio Visual Alarm Message | Air bubble, downstream occlusion, door open, infusion finish, standby time expired, battery low, battery empty, battery disengaged, AC Power disengaged, motor error, pump error, pressure sensor error, parameter error, system error |
Screen | 3.2inch brightness LCD |
Power Supply | AC Power:100V~240V,50Hz/60Hz,≤25VA |
Battery | Rechargeable Lithium battery, DC11.1V,3000mAh; operating time: ≥10h @25ml/h, displaying remaining battery |
Operation Condition | Temperature:+5℃~+40℃, Humidity:20%~90%, Air pressure:70~106KPa |
Transport & Storage | Temperature :-20℃~+55℃,Humidity:10%~95%, Air pressure:50~106KPa |
Classification | Type CF, Class I, IPX3 |
Dimension | 145mm×150mm×200mm;Weight:1.7kg |